Hypertherm XPR170 - Preflow;Charge DC State (7); Wait for Start State (5)

Hypertherm XPR170
428 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
6
210 810060 Instruction Manual XPR170
Pilot arc State (9)
Is the coolant flow within the acceptable range?
No
Continue to End of cycle
State (14)
Ye s
Are the gas pressures within the acceptable
range?
No
Ye s
Are the temperatures within the acceptable range?
No
Ye s
Is the DC bus voltage within the acceptable
range?
No
Ye s
Is the current for Chopper 1 within the acceptable
range?
No
Ye s
Is the current for the work lead within the
acceptable range?
No
Ye s
Does the Pilot arc State (9) complete within 500
milliseconds?
No
Diagnose and troubleshoot the problem. Refer to
Diagnostics and Troubleshooting on page 257.
Ye s
Continue to Rampup State (11) on page 211.