Diagnostics and Troubleshooting
8
302 810060 Instruction Manual XPR170
CAN codes (500 – 503, 510 – 513 for gas connect console, 504, 514 for CAN cable and jumper block,
507 508 for CAN network and bus, 600 602 for no CAN communication)
Multiple codes at the same time can indicate a problem with the CAN cable. If there is only one
code, the problem is more likely to be caused by what the code says (not the CAN cable).
1. Remove the power from the cutting system. Refer to Remove the power from the cutting system
on page 238.
2. For chopper-related codes, make sure that the chopper ID cable connector is fully engaged in
J8 on Chopper 1. If the chopper ID cable connection is good, continue with the following steps:
a. For code 504 alone:
Examine the CAN cable connection between Chopper 1 and the control board (PCB 1)
on the plasma power supply. Look for loose connections, bent pins, and bent sockets.
Tighten loose connections if found.
If you find bent sockets, order a new cable.
If you find a bent pin, try to straighten it. If this does not work, order a new cable.
WARNING
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before doing troubleshooting or diagnostic work.
All work requiring removal of the plasma power supply outer cover or panels
must be done by a qualified technician.
See the Safety and Compliance Manual (80669C) for more safety
information.