Installation
130 809480 Instruction Manual XPR300
1. Adjust the torch lead assembly so that the connectors in the torch lead assembly are aligned
with the corresponding receptacles in the TorchConnect console.
2. Connect the torch lead assembly to the TorchConnect console:
Use your hands to tighten the coupler on the torch lead assembly.
Do not use tools.
Connect the plasma valve cable to its connector. Use your fingers
to tighten this connection. Do not use tools.
Remove plug to access the ohmic wire if you
use a third-party ohmic circuit.