Diagnostics and Troubleshooting
272 810060 Instruction Manual XPR170
533
Alert
Low psi-F5 For a minimum of
200 milliseconds, the F5
pressure sensor (P7) is less
than 75% of setpoint.
1. Review the diagnostic code history for previous
pressure-related codes. Previous codes can
indicate where to look for flow or pressure
problems.
2. Make sure that the inlet gas pressure for Line A
(P2) or Line B (P1) are in the correct range.
3. If the measurement is too high or too low, use
the regulators to adjust the pressure for the
Line A/Line B gas or F5 gas to the correct
range.
4. Examine the consumables:
• Make sure that the correct consumables are
installed.
• Make sure that there is no damage or excess
wear.
5. Replace the incorrect consumables or
consumables that have damage or excess wear.
6. Use the gas volume monitors located near the
pressure transducers to look for gas leaks.
Ramp down Set process;
remote on-off
534
Alert
Low psi-Shield For a minimum of
600 milliseconds, the shield
gas pressure is less than
75% of the setpoint, and the
setpoint is more than 0.
Refer to Low shield gas pressure code (534) on
page 309.
Ramp down Set process;
remote on-off
540
Error
Low flow
1-Coolant
For a minimum of 40 seconds
after the Plasma Start switch
is turned ON, the coolant
flow rate is less than
1.9 L/min (0.5 gal/min).
Refer to Low coolant flow codes (540 – 542) on
page 310.
Shut down Remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action
Code cancels
with