Diagnostics and Troubleshooting
276 810060 Instruction Manual XPR170
574
Info
Start removed
preflow
The Plasma Start switch is in
the OFF position during
Preflow State.
Refer to Start switch diagnostic codes (570 – 577)
on page 316.
End of cycle Start or set
process;
remote on-off
575
Info
Start removed
ignite
The Plasma Start switch is in
the OFF position during
Ignite State.
End of cycle Start or set
process;
remote on-off
576
Info
Start removed pilot The Plasma Start switch is in
the OFF position during Pilot
arc State.
End of cycle Start or set
process;
remote on-off
577
Info
Start removed
rampup
The Plasma Start switch is in
the OFF position during a
Ramp-Up State.
End of cycle Start or set
process;
remote on-off
580
Error
Over temp-Ind1 The temperature of
Inductor 1 (1A) or 2 (1B) is
more than 160°C (320°F).
When conditions are normal,
it takes approximately 10
minutes for the XPR cutting
system to cool.
Over-temp codes can occur
when cooling takes more
than 10 minutes.
A high ambient temperature
can have an effect on cooling
time.
Refer to Over temp diagnostic codes – Inductor
(580 – 581), Transformers (586) on page 318.
Ramp down —
581
Error
Over temp-Ind2 Ramp down —
586
Error
Over temp-Xfmr For a minimum of 5 seconds,
the temperature of the
transformer is more than
160°C (320°F).
Refer to Over temp diagnostic codes – Inductor
(580 – 581), Transformers (586) on page 318.
Ramp down —
587
Error
Over temp-Coolant The coolant temperature is
more than 85°C (185°F).
Refer to Over temp diagnostic codes – Chopper
(560) and Coolant (587) on page 313.
Ramp down —
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action
Code cancels
with