Diagnostics and Troubleshooting
8
XPR170 Instruction Manual 810060 295
752
Error
Phase Fault Ch1 There is a 3-phase error in
Chopper 1.
1. Confirm the input-line voltage is within+/-14%
of nominal. Refer to Input power requirements
on page 42.
2. Remove the power from the cutting system.
3. Remove the cover from the contactor.
4. Inspect the contacts for excess wear. Replace
the contactor, if excess wear is found.
Otherwise, continue with the following steps.
5. Inspect the following contactor components for
loose connections:
Contactor
•Input to chopper
Power cord
6. Tighten loose connections if found. Otherwise,
continue with the following steps.
7. If the code continues, contact your cutting
machine supplier or regional Hypertherm
Technical Service team.
Shut down Remote on-off
755
Alert
Low level-Coolant The coolant level is low. Fill the coolant reservoir with coolant. Refer to
Coolant Installation on page 197.
None Set process;
remote on-off
Diagnostic code
number and
category
Diagnostic code
name
Description Corrective action XPR action
Code cancels
with

Table of Contents