3.5 Wiring connections (for cables)
3-13
3. Wiring
PLC wiring
For I/O between the PLC and signals, the wiring of the power I/O cable must
be connected to the PLC.
Connect the to wiring to the PLC terminal block while referring to
the connection diagram.
Connect the [orange] cable wire and the [Backward] output terminal.
Connect the [yellow] cable wire and the [Forward] output terminal.
Connect the [green] cable wire and the [Alarm clear] output terminal.
Connect the [blue] cable wire and the [Backward complete] input terminal.
Connect the [purple] cable wire and the [Forward complete] input terminal.
Connect the [gray] cable wire and the [Alarm] input terminal.
3
8
PLC connection
3
4
5
6
7
8
PLC
Process the terminals
in accordance with
PLC specifications
in order to conduct
wiring.
Enlarged view of power I/O
cable connector terminal section
ELECYLINDER/Power I/O cable