6.4 Parameter function descriptions
6-13
6. Parameters
Parameter No.8: Power-saving setting
No.
Category
Name
Symbol Unit Input range
Default setting
at shipping
8 A
Power-saving
setting
BUEN
Disabled,
enabled
Disabled
Either Enabled or Disabled can be selected for the ELECYLINDER power-saving setting.
When "Enabled," the power capacity can be reduced up to 40% compared to "Disabled"
mode, but the maximum speed, maximum acceleration/deceleration, and payload decrease in
comparison.
Refer to "Lead and Payload (Power-saving: Enabled)", "Stroke and Max Speed
(Power-saving: Enabled)", and "Payload by Speed/Acceleration (Power-saving: Enabled)" on
pages 1-8, 1-9, 1-14, 1-15, 1-20, 1-21, 1-26, 1-27, 1-32, 1-33, 1-37, 1-38, 1-42, 1-43, 1-47,
1-48, 1-55, 1-56, 1-60, and 1-61.
When "Disabled," the maximum speed, maximum acceleration/deceleration, and payload
increase compared to "Enabled" mode.
Refer to "Lead and Payload (Power-saving: Disabled)", "Stroke and Max Speed
(Power-saving: Disabled)", and "Payload by Speed/Acceleration (Power-saving: Disabled)" on
pages 1-6, 1-7, 1-12, 1-13, 1-18, 1-19, 1-24, 1-25, 1-30, 1-31, 1-35, 1-36, 1-40, 1-41, 1-45,
1-46, 1-53, 1-54, 1-58, and 1-59.