EasyManuals Logo

IAI EC-S7 User Manual

Default Icon
348 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #266 background imageLoading...
Page #266 background image
7.2 Troubleshooting diagnosis
7-5
7. Troubleshooting
[When an alarm is generated]
The alarm groups and warnings are as follows.
For details and countermeasures, see "7.4 Troubleshooting by alarm groups".
Alarm
group
Content Main content and typical countermeasures
A Overload alarm
[Content]
[Countermeasure]
Moving parts stopped abnormally.
Make sure that there are no
obstructions or obstacles.
B
Motor
error alarm
[Content]
[Countermeasure]
Motor abnormality occurred.
Replace the motor or controller.
C
Controller
error alarm
[Content]
[Countermeasure]
Controller abnormality occurred.
Replace the controller.
D
Controller-
encoder
abnormality
alarm
[Content]
[Countermeasure]
An abnormality occurred between the
controller and encoder.
Turn the power off and then on again.
If the unit still does not recover,
replace the motor or controller.
E
Power supply
voltage/Power
supply capacity
error alarm
[Content]
[Countermeasure]
Controller abnormality occurred.
Check the power supply voltage for any
abnormality.
Alarm
level
Content Main content and typical countermeasures
Warning
Maintenance
warning
[Content]
[Countermeasure]
The "maintenance period" has come to
an end.
Perform maintenance for the unit.

Table of Contents