EasyManua.ls Logo

IAI ROBO Cylinder RCS2 Series - Page 106

IAI ROBO Cylinder RCS2 Series
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
96
Grounding
wir
e
Nut (M3)
Shield wire
Cross-recessed flat-head screw (M3x8)
4) Pull out the relay connectors for the attached cables.
Motor connector Encoder connector
If the actuator is equipped with a brake, also remove the brake connector.
5) Remove the grounding and shield wires, and separate the attached cables.
Loosen the nut using a Phillips screwdriver and a 5.5-mm spanner wrench (or needle-nose pliers).
6) Remove the motor cover.
Remove the four hexagon socket-head button bolts using an Allen wrench of 2 mm across flats.

Table of Contents

Related product manuals