(4) Transmit to the Controller
Transmit the taken-in data to the controller.
Press the WRT key in the teaching screen condition.
Save the taken-in data to the controller memory.
Position No. will be increased 1 by pressing the
WRT key.
You can only transmit 1 screen of data to the
controller. You can’t transmit plural position No. data
at one time.
* If you change the screen with the PAGE UP ·
PAGE DOWN or ESC keys before transmitting
the data, the input data will be invalid.
(5) I/O Monitor · Location Confirmation
During teaching operation, you can monitor the input and output ports. You can also confirm the
location by moving an actuator to a to the location of the position data with teaching.
Input / Output Monitor
Select In or Out from the function keys in the teaching screen condition.
In: Input port Out: Output port
Input Port
Output Port
You can switch the status of the output port OFF/ON
(0/1) where the cursor is located by pressing the F1
(0/1) key.
(OFF/ON (0/1) status is switched each time you
press F1 key.)
54