13-3. Symbol Edit Screen of Each Items
(1) Constant Number
Select the F1 (Cnst) key on the constant number symbol edit screen.
Mode Transition:
Selection of Integer Type · Real Number Type Constant Number
Select an integer or real number.
F1 (ltg): Integer
F2 (Real): Real Number
Integer Type Constant Number Real Number Type Constant
Number
Mode Transition:
Integer Type Constant Number
Symbol Edit Screen
Mode Transition:
Real Type Constant Number Symbol
Edit Screen
(2) Variable
Select the F2 (Var) key on the variable symbol edit screen.
Mode Transition:
Selection of Integer Type · Real Number Type Variable
Select an integer or real number.
F1 (ltg): Integer
F2 (Real): Real Number
Integer Type Variable No. Real Number Type Variable
No.
Mode Transition:
Integer Type Variable No. Symbol Edit Screen
Mode Transition:
Real Number Type Variable No.
Symbol Edit Screen
Input alphabet and number.
Input constant value.
Input program No. at local area.
In
p
ut 0 at
g
lobal area.
Input alphabet and number.
Input variable No. by PAGE UP ·
PAGE DOWN key or 10 keys
84