NOTE:
To
place
the
carrier
in
the next to last
space,
proceed as follows:
a.
Space to the right until the carrier pointer lines
up
with the mark on the
RH
margin
set
lever.
b.
Backspace one
space.
3.
As
the
carrier
moves
from
the next to last to last
space,
check
for the following conditions (Fig. 185).
a.
The
contact
transfer must be complete (and without
bounce) within one
space.
b.
Nlc
contact
must
break.
c.
alp must lift the Nlo
contact
sufficiently to
en-
sure rei
iable
make.
Bell Ringer Bail
Contact Actuator
Slight
Rise
FIGURE
185. Last Column
Contact
Last
Column
Contact
(Fig. 186)
1.
With the
carrier
in
the
next to last
space,
the
contact
actuator
arm shall
be
adjusted to give
.010"
to
.020"
clearance
between the switch wire and the
actuator
arm
with
the switch
at
its re-transfer
point.
2.
The
actuator
arm shall be adjusted to
give.
120" to
.150"
left
to right
clearance
between the
actuator
arm
and the switch wire support.
3.
The
contact
backup spring shall be
so
adjusted
that
the
actuator
arm
wi
II
contact
the backup spring
.250"
to
.312"
before it contacts the switch
wire.
Last
Column
Contact
(Late) Fig. 186.
I)
- With
carrier
in the
last column, the
actuator
screw shall be adjusted to obtain
the
following:
I.
2.
Transfer the switch and have a .010"minimum overthrow
when escaping
from
the last column and
itwill
re-trans-
fer with a backspace
operation.
I>rovide
a
.005"
minimum
clearance
between the
actua-'
tor screw and the switch plunger, with
carrier
in last
column.
Pressure---
......
~
,..-~
/.120"
to •
ISO"
"
\
}
I
FIGURE
186.
Last Column Contact
Bell
Ringer
Bail
FIGURE
186.1.
Last Column
Contact
(Late)