Ethernet switches Code 8
Severity of the error
The element x indicates the severity of the error. The value x can be:
v A for Action: GUI error messages. The user must perform a specific action.
v C for Critical: A critical error occurred which must be corrected by the user or
system administrator.
v D for Debug: Used only for debug purposes.
v I for Informational: No operation action required.
v W for Warning: An error occurred that should be investigated and fixed.
Error code examples
These two error code examples illustrate how to interpret the alphanumeric
elements based on the information provided above.
Example 1
Source: Network problems between the third file module and the management
node.
Error code and message:
210000x The Ethernet port0 has failed and is unresponsive.
210001x A network failure was detected between Ethernet port 0 (mgmt0sl0) and
the management node. Link down.
210002x A network degradation was detected between Ethernet port 0
(mgmt0sl0) and the management node. There are high packet losses occurring.
210003x A network degradation was detected between Ethernet port 0
(mgmt0sl0) and the management node. High collisions detected.
The following table shows the break down of the error code's alphanumeric
elements:
Table 31. Error code break down
ACDXXXx
210nnnx
2 File Module
1 Built in Ethernet port 0
0 Originated with Denali checking
nnn Unique error code
x Severity of the error
Example 2
Source: A disk drive problem in the fourth storage pod, second expansion drawer.
Error code and message:
Chapter 4. File module 79

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified Series and is the answer not in the manual?

IBM Storwize V7000 Unified Series Specifications

General IconGeneral
Form Factor2U
Maximum Drives504
RAID Levels0, 1, 5, 6, 10
File ProtocolsNFS, CIFS/SMB, FTP, HTTP, HTTPS
Drive TypesSAS, SSD
Maximum Cache64 GB
Host Interface8 Gb FC, 16 Gb FC, 10 Gb iSCSI, 1 Gb iSCSI
File System SupportGPFS
Data ServicesThin provisioning, Easy Tier, FlashCopy, Remote Mirroring
Management InterfaceCLI
ScalabilityScale-out
Operating System SupportWindows, Linux, AIX, VMware
Power SupplyRedundant power supplies
Maximum CapacityUp to 4PB