Table 23. SMART ASC/ASCQ error codes and messages (continued)
ASC ASCQ Description
08 03 LOGICAL UNIT COMMUNICATION CRC ERROR (ULTRA-DMA/32)
08 04 UNREACHABLE COPY TARGET
09 00 TRACK FOLLOWING ERROR
09 04 HEAD SELECT FAULT
0A 00 ERROR LOG OVERFLOW
0B 00 WARNING
0B 01 WARNING - SPECIFIED TEMPERATURE EXCEEDED
0B 02 WARNING - ENCLOSURE DEGRADED
0B 03 WARNING - BACKGROUND SELF-TEST FAILED
0B 04 WARNING - BACKGROUND PRE-SCAN DETECTED MEDIUM
ERROR
0B 05 WARNING - BACKGROUND MEDIUM SCAN DETECTED MEDIUM
ERROR
0B 06 WARNING - NON-VOLATILE CACHE NOW VOLATILE
0B 07 WARNING - DEGRADED POWER TO NON-VOLATILE CACHE
0B 08 WARNING - POWER LOSS EXPECTED
0C 02 WRITE ERROR - AUTO REALLOCATION FAILED
0C 03 WRITE ERROR - RECOMMEND REASSIGNMENT
0C 04 COMPRESSION CHECK MISCOMPARE ERROR
0C 05 DATA EXPANSION OCCURRED DURING COMPRESSION
0C 06 BLOCK NOT COMPRESSIBLE
0C 0B AUXILIARY MEMORY WRITE ERROR
0C 0C WRITE ERROR - UNEXPECTED UNSOLICITED DATA
0C 0D WRITE ERROR - NOT ENOUGH UNSOLICITED DATA
0D 00 ERROR DETECTED BY THIRD PARTY TEMPORARY INITIATOR
0D 01 THIRD PARTY DEVICE FAILURE
0D 02 COPY TARGET DEVICE NOT REACHABLE
0D 03 INCORRECT COPY TARGET DEVICE TYPE
0D 04 COPY TARGET DEVICE DATA UNDERRUN
0D 05 COPY TARGET DEVICE DATA OVERRUN
0E 00 INVALID INFORMATION UNIT
0E 01 INFORMATION UNIT TOO SHORT
0E 02 INFORMATION UNIT TOO LONG
0E 03 INVALID FIELD IN COMMAND INFORMATION UNIT
10 00 ID CRC OR ECC ERROR
10 01 LOGICAL BLOCK GUARD CHECK FAILED
10 02 LOGICAL BLOCK APPLICATION TAG CHECK FAILED
10 03 LOGICAL BLOCK REFERENCE TAG CHECK FAILED
11 00 UNRECOVERED READ ERROR
11 01 READ RETRIES EXHAUSTED
66 Storwize V7000 Unified: Problem Determination Guide Version