Loading...
If a drive were not synchronized, the status might appear like the status shown
in Figure 9 on page 62:
Mirror Information: <---
Volume ID : 3
Status of volume : Resyncing (RSY) <---
RAID level : 1
Size (in MB) : 285148
Physical hard disks (Target ID) : 6 5 <---
Current operation : Synchronize <---
Physical disk I/Os : Not quiesced
Volume size (in sectors) : 583983104
Number of remaining sectors : 553462899
Percentage complete : 5.23% <---
Drive Information:
Total number of drives found: 2
Target on ID #5
Device is a Hard disk
Enclosure # : 1
Slot # : 1
Connector ID : 1
Target ID : 5
State : Ready (RDY)
Size (in MB)/(in sectors) : 286102/585937500
Manufacturer : IBM-ESXS
Model Number : XXXXXXXXXXXX
Firmware Revision : XXXX
Serial No : XXXXXXXXXXXXXXXXXXXX
Drive Type : SAS
Protocol : SAS
Error Information
SMART Error Count : none
SMART ASC : none
SMART ASCQ : none
Target on ID #6 <---
Device is a Hard disk
Enclosure # : 1
Slot # : 0
Connector ID : 0
Target ID : 6
State : Online (ONL)
Size (in MB)/(in sectors) : 286102/585937500
Manufacturer : IBM-ESXS
Model Number : XXXXXXXXXXXX
Firmware Revision : XXXX
Serial No : XXXXXXXXXXXXXXXXXXXX
Drive Type : SAS
Protocol : SAS
Error Information
SMART Error Count : none
SMART ASC : none
SMART ASCQ : none
Figure 8. Example that shows that mirroring is re-synchronizing
Chapter 4. File module 61