As NTP is drift based, large time differences can prevent NTP from synchronizing,
or cause synchronization to take a long time. It can be helpful to synchronize time
manually once and to verify that the time is picked up correctly afterward. Use the
separate commands of service ntpd stop , ntpdate your IP, and service ntpd
start. The following example shows the sequence:
[root@domain.node ~]# service ntpd stop
Shutting down ntpd: [ OK ]
[root@domain.node ~]# ntpdate 9.19.0.220
14 Jan 12:06:46 ntpdate[25360]: adjust time server 9.19.0.220 offset 0.003277 sec
[root@domain.node ~]# service ntpd start
Starting ntpd: [ OK ]
[root@domain.node ~]#
After the time on all of the servers is synchronized, you can verify that the logs
apply to your troubleshooting situation.
172 Storwize V7000 Unified: Problem Determination Guide Version

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified Series and is the answer not in the manual?

IBM Storwize V7000 Unified Series Specifications

General IconGeneral
Form Factor2U
Maximum Drives504
RAID Levels0, 1, 5, 6, 10
File ProtocolsNFS, CIFS/SMB, FTP, HTTP, HTTPS
Drive TypesSAS, SSD
Maximum Cache64 GB
Host Interface8 Gb FC, 16 Gb FC, 10 Gb iSCSI, 1 Gb iSCSI
File System SupportGPFS
Data ServicesThin provisioning, Easy Tier, FlashCopy, Remote Mirroring
Management InterfaceCLI
ScalabilityScale-out
Operating System SupportWindows, Linux, AIX, VMware
Power SupplyRedundant power supplies
Maximum CapacityUp to 4PB