Table 6. Error messages and actions (continued)
Error code Error message Action key
0AFF Unable to write clock file. A
0B00 Unable to write to /etc/ntp.conf. A
0B01 Unable to parse internal IP range. D
0B08 Unable to open dhcpd.conf template file. A
0B09 Unable to open dhcpd.conf for writing. A
0B0A Unable to copy dhcpd.conf to /etc/. A
0B0B Unable to copy tftp to /etc/xinetd.d. A
0B0E Unable to enable the TFTP server. A
0B12 sonas_setup_security is not present. A
0B13 No service IP provided. D
0B14 Unable to create RSA1 SSH keys. A
0B15 Unable to create RSA SSH keys. A
0B16 Unable to create DSA SSH keys. A
0B17 Exiting on trap. A
0B18 No controllers found in this cluster. A
0B2F Unable to set GPFS setting. Check logs for more
details.
A
0B30 Unable to query current GPFS settings from
mmlscluster.
A
0B31 There was an error while attempting to enable CTDB. A
0B32 Unable to query current GPFS settings mmlsconfig. A
0B33 Unable to open settings file. Check logs for more
details.
A
0B34 Invalid arguments passed to the script. A
0B4F add_new called with improper parameters. A
0B50 Invalid serial number. B
0B51 Invalid forced ID. A
0B52 Invalid site. A
0B53 Node with serial was not found in available list. B
0B54 Storage nodes must be added in pairs. Invalid peer
serial.
A
0B55 Storage node peer must be a different serial. A
0B56 Peer node is not a storage node. A
0B57 There is already a node with ID. A
0B58 There is a node at the peer's ID. A
0B59 No existing cluster found. Node ID must be
specified.
A
0B5A Unable to determine management IP address of this
node.
A
0B5B Unknown node type. B
0B5C IP address conflict detected with the management IP.
There is a node that already has this IP address.
D
16 Storwize V7000 Unified: Problem Determination Guide Version

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V7000 Unified Series and is the answer not in the manual?

IBM Storwize V7000 Unified Series Specifications

General IconGeneral
Form Factor2U
Maximum Drives504
RAID Levels0, 1, 5, 6, 10
File ProtocolsNFS, CIFS/SMB, FTP, HTTP, HTTPS
Drive TypesSAS, SSD
Maximum Cache64 GB
Host Interface8 Gb FC, 16 Gb FC, 10 Gb iSCSI, 1 Gb iSCSI
File System SupportGPFS
Data ServicesThin provisioning, Easy Tier, FlashCopy, Remote Mirroring
Management InterfaceCLI
ScalabilityScale-out
Operating System SupportWindows, Linux, AIX, VMware
Power SupplyRedundant power supplies
Maximum CapacityUp to 4PB