Table 6. IMM2 error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
806f0107-0301xxxx The Processor CPU
Status has been
detected an
over-temperature
condition.
Error An over
temperature
condition has
occurred.
1. Make sure that the latest levels of
firmware and device drivers are
installed for all adapters and
standard devices, such as
Ethernet, SCSI, and SAS.
Important: Some cluster solutions
require specific code levels or
coordinated code updates. If the
device is part of a cluster solution,
verify that the latest level of code
is supported for the cluster solution
before you update the code.
2. Update the firmware (UEFI and
IMM2) to the latest level (see
“Updating the firmware” on page
267).
3. Run the DSA program.
4. Reseat the adapter (see
“Removing a ServeRAID adapter”
on page 176 and “Installing a
ServeRAID adapter” on page 178).
5. Replace the adapter.
6. (Trained technician only) Replace
microprocessor (see “Removing
the microprocessor and heat sink”
on page 250 and “Installing a
microprocessor and heat sink” on
page 254).
7. (Trained technician only) Replace
the system board (see “Removing
the system board” on page 258
and “Installing the system board”
on page 261).
806f0207-0301xxxx The Processor CPU
Status has Failed with
BIST condition.
Error A processor failed
- BIST condition
has occurred.
1. Make sure that the fans are
operating. There are no
obstructions to the airflow (front
and rear of the server), the air
baffles are in place and correctly
installed, and the server cover is
installed and completely closed.
2. Make sure that the heat sink for
microprocessor is installed
correctly.
3. (Trained service technician only)
Replace microprocessor (see
“Removing the microprocessor and
heat sink” on page 250 and
“Installing a microprocessor and
heat sink” on page 254).
Chapter 3. Diagnostics 43

Table of Contents

Other manuals for IBM System x3100 M4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3100 M4 and is the answer not in the manual?

IBM System x3100 M4 Specifications

General IconGeneral
MemoryUp to 32 GB DDR3 ECC UDIMM
Memory Slots4 DIMM slots
Form FactorTower
ChipsetIntel C202
Processor Sockets1
ProcessorIntel Xeon E3-1200 v2 series, Intel Pentium series, Intel Celeron series
StorageUp to 4x 3.5-inch
Power Supply350W
Hard Drive Bays4 x 3.5"
RAID SupportRAID 0, 1, 10
Network InterfaceGigabit Ethernet
Expansion Slots1 x PCIe 3.0 x16, 1 x PCIe 2.0 x4
Operating System SupportWindows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server