Table 44. Power consumption of TS3500 Tape Library frame models, power consuming
features, and drive canisters (continued)
FC 1950 PDU 5 17 17
FC 4872
TS7700 backend 4 Gb
switches (2x)
0 113 113
FC 4875
TS7700 backend 8 Gb
switches (2x)
08686
Tape Drives
6
TS1120 (3592 Models
E05 and J1A)
02742
TS1130 (3592 Model
E06)
01746
TS1140 (3592 Model
E07)
02350
TS1030 (LTO 3588
F3B)
02034
TS1040 (LTO 3588
F4A)
01836
TS1050 (LTO 3588
F5A)
01228
TS1060 (LTO 3588
F6A)
0932
Notes:
1. These models come equipped with dual ac line cords. The figures in this table show the
total power consumed, including power consumed by redundant power supplies. Each
individual line cord supplies approximately half of the power.
2. Frames with no frame control assembly (FCA) or enhanced FCA consume no power
and require no cooling.
3. S-frame power is for internal lighting and is provided by the power supplies in frames
that are equipped with power.
4. The HA1 frame is not connected to ac power. The power shown is the total consumed
by the second accessor and is provided by the power supplies in frames that are
equipped with power.
5. Drive mounting kit power includes ac/dc conversion losses in drive power supplies
(including redundant power), but does not include power consumed by the drive
canister.
6. Drive power includes the drive and canister cooling fan, but does not include power
losses in external ac or dc drive power supplies. Idle power is consumed when the
drive has no tape cartridge loaded. Maximum continuous power is consumed when the
drive is actively writing to a tape cartridge.
7. "Off" refers to power consumed when the library is connected to an ac power source
and the library on/off switch is set to off.
8. Model SC1 power is provided by the library frames to which it connects. The idle
power is the power consumed by each shuttle station when no shuttle car is present.
The maximum continuous power is the power consumed by the shuttle station when
the shuttle car is present.
In order to calculate the total power consumption (in watts) of a particular library
configuration, multiply the quantity of each power consuming item in the
configuration by the corresponding value in Table 44 on page 120 and calculate the
Chapter 2. Physical planning specifications 121
|
|
|||

Table of Contents

Other manuals for IBM TS3500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS3500 and is the answer not in the manual?

IBM TS3500 Specifications

General IconGeneral
TypeTape Library
ModelTS3500
Max. drivesUp to 192
InterfaceFibre Channel, SAS
EncryptionYes
Tape TechnologyLTO, IBM TS11xx
Drive supportIBM TS1160

Related product manuals