v Boot sequence manipulation.
v Command-line interface.
v Configuration save and restore.
v DIMM error assistance. The Unified Extensible Firmware Interface (UEFI)
disables a failing DIMM that is detected during POST, and the IMM lights the
associated system-error LED and the failing DIMM error LED.
v Environmental monitor with fan speed control for temperature, voltages, fan
failure, and power supply failure.
v Intelligent Platform Management Interface (IPMI) Specification V2.0 and
Intelligent Platform Management Bus (IPMB) support.
v Invalid system configuration (CNFG) LED support.
v Light path diagnostics LEDs to report errors that occur with fans, power
supplies, microprocessor, hard disk drives, and system errors.
v Nonmaskable interrupt (NMI) detection and reporting.
v Operating-system failure blue screen capture.
v PCI configuration data.
v PECI 2 support.
v Power/reset control (power-on, hard and soft shutdown, hard and soft reset,
schedule power control).
v Query power-supply input power.
v ROM-based IMM firmware flash updates.
v Serial over LAN (SOL).
v Serial port redirection over Telnet or SSH.
v System-event log.
v When one of the two microprocessors reports an internal error, the server
disables the defective microprocessor and restarts with the one good
microprocessor.
The IMM also provides the following remote server management capabilities
through the OSA SMBridge management utility program:
v Command-line interface (IPMI Shell)
The command-line interface provides direct access to server management
functions through the IPMI 2.0 protocol. Use the command-line interface to issue
commands to control the server power, view system information, and identify
the server. You can also save one or more commands as a text file and run the
file as a script.
v Serial over LAN
Establish a Serial over LAN (SOL) connection to manage servers from a remote
location. You can remotely view and change the UEFI settings, restart the server,
identify the server, and perform other management functions. Any standard
Telnet client application can access the SOL connection.
212 IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM X3950 X5 and is the answer not in the manual?

IBM X3950 X5 Specifications

General IconGeneral
BrandIBM
ModelX3950 X5
CategoryServer
LanguageEnglish

Related product manuals