Embedded hypervisor problems
This topic provides suggested actions for correcting problems with the embedded
hypervisor.
About this task
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, “Parts listing, Types 7145, 7146, 7143, and 7191,” on page 81 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
An embedded hypervisor
device is not listed in the
expected boot order, or is not in
the list of boot devices, or a
similar problem has occurred.
1. Make sure the embedded hypervisor device is selected in the boot menu (in
the Setup utility and in Select Boot Device).
2. If the embedded hypervisor is on an internal flash memory device, make sure
that the internal flash memory device is seated in the connector correctly (see
“Removing the internal flash memory” on page 140 and “Replacing the
internal flash memory” on page 141).
3. See the documentation that comes with the embedded hypervisor for setup
and configuration information.
4. Make sure that other software works on the server.
General problems
This topic provides solutions for general problems with the server.
About this task
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 4, “Parts listing, Types 7145, 7146, 7143, and 7191,” on page 81 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
An LED is not working or a
similar problem has occurred.
If the part is a CRU, replace it. If the part is a FRU, the part must be replaced by a
trained service technician (see “Replaceable server components” on page 83 to
determine whether the part is a CRU or a FRU).
Power LED blinks quickly or
system can't be powered on.
1. Reseat the system.
2. See “Confirm and recover IMM boot image failure” on page 75.
44 IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide