806f0021-0b04ffff Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Explanation: IMM has detected a Fault in PCIe slot 1.
May also be shown as 806f00210b04ffff or 0x806f00210b04ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1. Check the I/O board LEDs.
2. Reseat the affected adapters.
3. Update the server and adapter firmware (UEFI and IMM).
4. Remove the adapter from the slot.
5. Replace the PCI Express adapter.
806f0021-0b05ffff Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Explanation: IMM has detected a Fault in PCIe slot 2.
May also be shown as 806f00210b05ffff or 0x806f00210b05ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response:
1. Check the I/O board LEDs.
2. Reseat the affected adapters.
3. Update the server and adapter firmware (UEFI and IMM).
4. Remove the adapter from the slot.
5. Replace the PCI Express adapter.
806f0021-0b04ffff 806f0021-0b05ffff
450
IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide