806f000f-22010cff CPU voltage mismatch detected on [ProcessorElementName].
Explanation: IMM has detected a CPU voltage mismatch with the CPU socket voltage.
May also be shown as 806f000f22010cff or 0x806f000f22010cff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0050
SNMP Trap ID: 40
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Info Center
for the appropriate user response.
806f000f-2201ffff The System [ComputerSystemElementName] encountered a POST Error.
Explanation: IMM has detected a Post Error.
May also be shown as 806f000f2201ffff or 0x806f000f2201ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0184
SNMP Trap ID:
Automatically notify Support: No
User response:
1. Recover the UEFI firmware from the backup UEFI image.
2. Update the UEFI firmware to the latest level.
3. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of
a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the
code.
806f001b-1f07ffff The network port [ManagedElementName] has been connected.
Explanation: EXA Cable 1 is connected
May also be shown as 806f001b1f07ffff or 0x806f001b1f07ffff
Severity: Info
Alert Category: Warning
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0262
SNMP Trap ID: 60
Automatically notify Support: No
User response: Information only; no action is required.
806f000f-22010cff • 806f001b-1f07ffff
448
IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide