218-806-000 Brocade:InternalLoopbackTest Aborted
Explanation: The test was canceled.
Severity: Warning
Serviceable: No
Recoverable: No
Automatically notify Support: No
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
218-900-000 Brocade:MemoryTest Failed
Explanation: A failure was detected while testing the adapter memory.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Rerun the test.
2. Verify whether the firmware is at proper level.
3. Rerun the test.
4. If the problem remains, contact your IBM technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
218-901-000 Brocade:ExternalLoopbackTest Failed
Explanation: A failure was detected during the Loopback test.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify whether the firmware is at proper level.
4. Rerun the test.
5. If the problem remains, contact your IBM technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
218-806-000 218-901-000
Appendix A. DSA diagnostic test results 241

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM X3950 X5 and is the answer not in the manual?

IBM X3950 X5 Specifications

General IconGeneral
BrandIBM
ModelX3950 X5
CategoryServer
LanguageEnglish

Related product manuals