EasyManua.ls Logo

IBM X3950 X5 - Page 270

IBM X3950 X5
1064 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
217-800-000 HDD Test Aborted
Explanation: HDD Test Aborted. The test was canceled.
Severity: Warning
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify that Hard drive supports self test and self test logging.
4. If the problem remains, contact your technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
217-900-000 HDD Test Failed
Explanation: HDD Test Failed. The hard drive self-test detected a failure.
Severity: Error
Serviceable: Yes
Recoverable: No
Automatically notify Support: No
User response: Complete the following steps:
1. Check cable connections.
2. Rerun the test.
3. Verify the firmware is at the latest level.
4. Rerun the test.
5. If the problem remains, contact your technical-support representative.
Related Links:
v IBM Support Website
v Latest level of DSA
v Latest level of BMC/IMM
217-800-000 217-900-000
254
IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide

Table of Contents

Related product manuals