80070608-1415ffff Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: A system power fault has occurred.
May also be shown as 800706081415ffff or 0x800706081415ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response: (Trained service technician only) Replace the CPU board.
80070608-1881ffff Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: IMM has detected MEU Power Supply related fault. (PS 12V OC Fault, PS 12V OV Fault, PS 12V UV
Fault, or PS AUX UV Fault)
May also be shown as 800706081881ffff or 0x800706081881ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: No
User response:
1. Check MEU power supply LEDs, see "Power-supply LEDs".
2. Replace the failing power supply.
80070608-2201ffff Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: System power on is blocked due to an over-current issue.
May also be shown as 800706082201ffff or 0x800706082201ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: Yes
User response:
1. Check the checkpoint value (for example, F/A:6:9) displayed in light path.
2. (Trained service technician only) Replace the CPU board or I/O board according to the checkpoint value.
80070608-1415ffff 80070608-2201ffff