806f010d-0408ffff The Drive [StorageVolumeElementName] has been disabled due to a detected fault.
Explanation: The drive 8 has been disabled (defunct) due to a fault detected by the controller.
May also be shown as 806f010d0408ffff or 0x806f010d0408ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
2. Check IBM Support site for firmware updates related to your particular drive.
3. Check for any other RAID related errors.
4. Replace the drive.
806f010d-0409ffff The Drive [StorageVolumeElementName] has been disabled due to a detected fault.
Explanation: The drive 9 has been disabled (defunct) due to a fault detected by the controller.
May also be shown as 806f010d0409ffff or 0x806f010d0409ffff
Severity: Error
Alert Category: Critical
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0164
SNMP Trap ID: 5
Automatically notify Support: Yes
User response:
1. Check IBM Support site for Service Bulletins/RETAIN tips related to your particular drive.
2. Check IBM Support site for firmware updates related to your particular drive.
3. Check for any other RAID related errors.
4. Replace the drive.
806f010d-0408ffff • 806f010d-0409ffff
Appendix B. Integrated management module error messages 511