EasyManua.ls Logo

IBM X3950 X5 - Page 532

IBM X3950 X5
1064 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. If the sensor name is "QPI Wrap Card x",
5. a) the QPI wrap card, if installed.
6. b) Reseat any installed QPI cables. Attention: Do not disconnect or connect any of the cables when the server or
memory expansion module has power connected.
7. c) Replace the CPU board.
8. If the sensor name is "USB Detect",
9. a) Make sure that all the USB cables are connected and that there is no damage to the connectors.
10. b) Check the internal cable from the I/O board to the system front panel.
806f011b-1801ffff The connector [PhysicalConnectorElementName] has encountered a configuration error.
Explanation: An internal memory expansion module FPGA error has occurred.
May also be shown as 806f011b1801ffff or 0x806f011b1801ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0266
SNMP Trap ID: 50
Automatically notify Support: No
User response:
1. Make sure that the QPI cables from the server to the memory expansion module are securely and properly
attached.
2. Make sure that the latest level of firmware is installed on the memory expansion module and the server.
806f011b-1f05ffff The connector [PhysicalConnectorElementName] has encountered a configuration error.
Explanation: A fan cable configuration error has occurred.
May also be shown as 806f011b1f05ffff or 0x806f011b1f05ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0266
SNMP Trap ID: 50
Automatically notify Support: No
User response: Make sure that the cable is connected securely and properly.
806f011b-1801ffff 806f011b-1f05ffff
516
IBM System x3850 X5 and x3950 X5 Types 7145, 7146, 7143, and 7191: Problem Determination and Service Guide

Table of Contents