806f011b-1f09ffff The connector [PhysicalConnectorElementName] has encountered a configuration error.
Explanation: A cable configuration error has occurred.
May also be shown as 806f011b1f09ffff or 0x806f011b1f09ffff
Severity: Error
Alert Category: Critical
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0266
SNMP Trap ID: 50
Automatically notify Support: No
User response: Make sure that the cable is connected securely and properly.
806f0123-2101ffff Reboot of system [ComputerSystemElementName] initiated by [WatchdogElementName].
Explanation: The IPMI Watchdog Timer has expired. A reboot of the system was initiated.
May also be shown as 806f01232101ffff or 0x806f01232101ffff
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0370
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
806f0125-0c01ffff [ManagedElementName] detected as absent.
Explanation: IMM has detected the Operator Information panel is absent.
May also be shown as 806f01250c01ffff or 0x806f01250c01ffff
Severity: Info
Alert Category: System
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0392
SNMP Trap ID:
Automatically notify Support: No
User response:
1. Reinsert or replace the operator information panel cable.
2. Replace the operator information panel.