806f020d-0404ffff Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName].
Explanation: Failure predicted (PFA) on the hard drive 4.
May also be shown as 806f020d0404ffff or 0x806f020d0404ffff
Severity: Warning
Alert Category: Warning
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response: Replace the hard disk drive at the next maintenance period.
806f020d-0405ffff Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName].
Explanation: Failure predicted (PFA) on the hard drive 5.
May also be shown as 806f020d0405ffff or 0x806f020d0405ffff
Severity: Warning
Alert Category: Warning
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response: Replace the hard disk drive at the next maintenance period.
806f020d-0406ffff Failure Predicted on drive [StorageVolumeElementName] for array
[ComputerSystemElementName].
Explanation: Failure predicted (PFA) on the hard drive 6.
May also be shown as 806f020d0406ffff or 0x806f020d0406ffff
Severity: Warning
Alert Category: Warning
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response: Replace the hard disk drive at the next maintenance period.