EasyManua.ls Logo

Icom IC-440 - RX Frequency Setting (for RX Channels Only); Rx Frequency Programming; Rx Channel Setting

Icom IC-440
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
35
8
OTHER FUNCTIONS
8
RX frequency setting (for RX channels only)
The receive frequency in the RX channels can be re-pro-
grammed within 450 to 520 MHz frequency range depending
on the setting.
D RX channel setting
The RX channels does not appear on the LCD (default; “In-
hibit” setting) and you cannot select it. So the RX channels
should be set to “Enable” before programming the RX fre-
quency.
q While pushing and holding
SCAN
TAG
*
and
LOW
*
, turn power ON
to indicate all pre-programmed RX channels (including
the inhibited channels.)
w Select the desired channel with
or , then push
SCAN
TAG
*
to set the displayed channel “Enable.
e Turn the power OFF, then ON.
The “Enable” channels appear on the LCD, and push
CH
SQL
then
push
/ to select the desired RX channel.
D RX frequency programming
q Select the desired RX channel (‘RX-XX’). (See at left)
w Push
F
SET
(Function) to enter the function mode, then push
and hold
F
SET
(RX VFO) for 2 sec. to enter the RX VFO
mode.
Push
LOW
*
to toggle the bandwidth between wide or narrow.
e Push or several times to select the desired fre-
quency.
The frequency changes according to the Wide/Narrow setting.
(p. 37)
*Regardless of the assigned key function.
“Inhibit” setting “Enable” setting
RX channel
(in function mode)
RX VFO mode
Appears when
Narrow channel
spacing is set.
*
Wide channel spacing
(25 kHz steps)
Narrow channel spacing
(12.5 kHz steps)
IC-440-1.indd35IC-440-1.indd35 2008/06/2515:59:412008/06/2515:59:41