22
(*4)
Accuracy
± (0.1% + 0.05 sec)
Delay Timer (*4)
Range
1s~999.9s
0.1m~999.9m
0.1h~999.9h
Resolution
0.1(s,m,h)
Accuracy
± (0.1% + 0.1 sec)
Dwell Timer (*4)
Range
0, 1s~999.9h (0=continuous)
Resolution
0.1(s,m,h)
Accuracy
± (0.1% + 0.1 sec)
Poly-phase
mode(1Ø3W) for
per-phase
measurement
(Option)
Frequency
Range
0.0-1000Hz
Resolution
0.1Hz
Accuracy
±0.1Hz (501-1000Hz Accuracy ±0.2Hz)
Voltage
Range
0.0-420.0V
Resolution
0.1V
Accuracy
± (0.2% of reading + 3counts)
Current(r.m.s) (*5)
Range
L
0.005A~1.200A
0.005A~2.400A
H
1.00A~13.00A
2.00A~26.00A
Resolution
L
0.001A
H
0.01A
Accuracy
L
± (1% of reading +5counts) at 40.0-500Hz
± (1% of reading +5counts) at 501-1000Hz
and CF<1.5
Current (peak)3.6A
± (1% of reading +5counts) at 40.0-
500Hz
± (1% of reading +5counts) at 501-
1000Hz and CF<1.5
Current (peak)7.2A
H
± (1% of reading +5counts) at 40.0-500Hz
± (1% of reading +5counts) at 501-1000Hz
and CF<1.5
Current (peak)27.6A
± (1% of reading +5counts) at 40.0-
500Hz
± (1% of reading +5counts) at 501-
1000Hz and CF<1.5
Current (peak)55.2A
Current(peak) (*5)
Range
0.0A~38.0A
0.0A~76.0A
Resolution
0.1A

Table of Contents