P39
Restore Default Settings
The Restore Defaults option allows you to quickly clear
all conguration settings from the SCRP Switched Relay
Controller and return it to its standard factory condition.
To restore default settings
1. From the Conguration menu, highlight the ‘Restore
Defaults’ entry and press the
ENT
button. The follow-
ing options will be displayed:
2. Ensure that the ‘Yes’ option is highlighted and press
the
ENT
button. The display will show the following
warning:
Restore Defaults
Yes
No
Restore Defaults
WARNING
THIS WILL CLEAR
ALL CONFIGURATION
Press ENTtoproceed
3. If you are sure that you wish to proceed, press the
ENT
button to clear all settings and return to the Congura-
tion menu.
CommunicationsOptions
iCANnet
Ethernet
DMX
RS485
Contact Inputs
ON
OFF
OFF
OFF
OFF
Choose Communications
This option allows you to enable/disable any of the con-
trol communication methods used by the SCRP Switched
Relay Controller. This may be useful, for instance, when
temporary control methods are introduced and standard
ones need to be suspended.
This feature can also be useful when diagnosing control
problems on SCRP Switched Relay Controller with multi-
ple control inputs. The ability to quickly disable any input
can help to isolate the problem.
To choose communications
1. From the Operation menu, highlight the ‘Communica-
tions’ option and press the
ENT
button. The display
will show the current status of each control input:
2. Use the
or
buttons to highlight the required
option and then use the
or
buttons to change
the highlighted option between ‘ON’ and ‘OFF’.
3. Press the
ESC
button to return to the Operation menu.