EasyManuals Logo

Immergas AUDAX TOP ErP Series User Manual

Immergas AUDAX TOP ErP Series
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
AUDAX TOP ErP and Integrated System
8
Each time AUDAX TOP ErP is operating, the Manager enables
an additional control, which checks the time it takes the system
to reach full operation: when a maximum time is exceeded (can
be set dierently between C.H. and D.H.W.) for the heat pump
to reach the owT, the boiler or integrative electrical resistance
is started.
It is also possible to choose the integration operation method
(boiler/resistance) between simultaneous or alternative Heat
Pump.
In all cases where radiant panels are also included for summer
cooling, alongside dehumidiers (see previous picture), the
System Manager will also monitor the dew point through the
installation of room probes (Immergas). anks to this intelligent
function the System Manager can increase the ow temperature
to the radiant panels by about 1°C (up to a maxT of 18°C - maxi-
mum limit of the cooling heat pump), avoiding the phenomenon
of condensation on the surface of the structure. is function can
only be activated with an Immergas accessory kit that controls
humidity. In some cases, for example, the System Manager can
turn the heat pump o if the ow temperature to the radiant
panels is not suciently corrected.
If on the other hand, there is a high temperature zone in the
system, in addition to the low temperature one, it will be served
exclusively by the boiler through an accordingly congured
dedicated expansion connected to the System Manager.
D.H.W: operation: amongst the possible congurations with
integrated systems is the option to connect the boiler and
AUDAX TOP ErP parallel with the same coil, and use a storage
tank probe with one DHW set for the entire storage tank, and set
it in the system's Manager. If the system Manager is connected
to the boiler on external probe clamps (pre-set models), if the
set DHW temperature is < 50°C, the heat pump starts (always
checking the aforesaid convenience); however, if it is > 50°C,
AUDAX TOP ErP heats up to 50°C, then the boiler starts; if
there is no boiler but there is storage tank integrative electrical
resistance, the water is brought to 50°C via the heat pump and
AUDAX TOP ErP is then disabled, leaving the resistance to
integrate to the pre-set value.
In systems where there is a boiler or an integrative electrical
resistance on the storage tank, in addition to the heat pump, it
is also possible to enable the anti-legionella function.
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua
voltar.com.ua

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Immergas AUDAX TOP ErP Series and is the answer not in the manual?

Immergas AUDAX TOP ErP Series Specifications

General IconGeneral
BrandImmergas
ModelAUDAX TOP ErP Series
CategoryHeat Pump
LanguageEnglish

Related product manuals