e.g. vertically 6 standards and 3 replicates defined:
Note: It is necessary to measure all defined blanks (horizontally 12 and vertically 8) as they
might be needed for sample measurements.
11. Measure blanks and standards as defined by initiating the blank button for blank
measurements and sample button for the standard measurements. Results will be shown in
the table of the standard map. Once all standards are measured the screen changes
automatically to the standard curve screen.
12. In the graph screen the standard curve is shown and if replicates are
defined the results and mean calculation of each standard. It is possible to
exclude single standard measurements with the toggle switches and
standard curve is recalculated.
Note: After the first sample measurement the standard curve can no longer
be altered.
14. After the standard curve is finished, swipe the screen to the left and the sample map screen
is shown.