53
7 Technical data
Main dimensions:
Cutter drive (NW 250): approx. L 1150 x W 190 x H 175 mm
approx. 45” x 7,5 x 6.9
Chassis with drum, hose package and control unit:
approx. L 790 x W 630 x H 1050 mm
approx. 31“ x 25“ x 41“
Weight:
Cutter drive (NW 250): approx. 21 kg
Chassis with drum, hose package 100 m/328 ft and control unit:
approx. 88 kg
Applications: Pipes with interior diameter 135 400 mm/5.3” – 15.7”
Protection class: IP 54 (protected against access with a wire, dust and water
splashes from all sides)
Temperature range: +5 ... +40C (41°F to max. 104°F)
Power supply: 100 240 VAC, 47 63 Hz, max. 7,4 A
Supply air: Contaminant free (particles < 5 micrometers)
Temperature range 5 °C to max. 40 °C
(41 °F to max. 104 °F)
Residual water separated
Residual oil < 5 mg/m³
Supply line pressure 10 bar (145 PSI)
Min. volume flow 1 m
3
/min (35 CFM)
Water supply: Distilled water from a canister/bottle