User Guide - v7 59
• Signal Impedance: 75 ohms
Network connections
• RJ45 connector for connecting to the network. The network connection must be made
using CAT5 (or higher spec) twisted pair cable.
• Maximum cable length is 100 metres. The network cable must use straight through
wiring.
Environment
Internal and Standard Vandal Resistant variants:
• Operating temperature: 0°C (32°F) to + 40°C (104°F)
• Storage temperature: -20°C (-4°F) to + 70°C (158°F)
Environmental Vandal Resistant variant:
• Operating temperature: -30°C (-22°F) to + 50°C (122°F)
• Storage temperature: -20°C (-4°F) to + 70°C (158°F)
Regulatory and approvals
• EN 55022(2010) ITE emission standard – Class A
• EN55024(1998 + A1, A2) ITE immunity standard
• 47CFR(2008) Part 15 subpart B – Class A (US federal code of regulations)
• This product complies with the European Low Voltage Directive 73/23/EEC and EMC
Directive 89/336/EEC as amended by European Directive 93/68/EEC
• EN60529 (1992) IP66 Dust and Water Ingress (Vandal Resistant variant only)
• UL60950-1 Standard for Information Technology Equipment – Safety – Part 1. (In-
ceiling variant only)
• UL2043 Standard for Fire Test for Heat and Visible Smoke Release for Discrete
Products and Their Accessories Installed in Air-Handling Spaces (In-ceiling variant
only)
• This product meets the requirements of the EC restriction of hazardous substances
(RoHS) directive 2002/95/EC
In accordance with the EC Waste Electrical and Electronic Equipment (WEEE) directive
2002/96/EC this product must be sent to a recycling plant for proper disposal at the end of its
use.
Enhanced SDFixed Dome - 9000 Range 7 Hardware Specification