TLE5012B
Pre-Configured Derivates
User’s Manual 104 Rev. 1.2, 2018-02
7.6 Fuse Values
The derivate specific reset values for the configuration registers, which are stored in laser fuses on the sensor, are
shown in Figure 7-1.
Figure 7-1 Derivate-specific fuse settings
CLK_SEL DSPU_HOLD
TLE5012B E1000 (IIF)
01 0 0 01
TLE5012B E3005 (HSM)
01 0 0 00
TLE5012B E5000 (PWM)
10 0 0 00
TLE5012B E5020 (PWM)
01 0 0 00
TLE5012B E9000 (SPC)
10 0 0 00
msb lsb
IIF_ MODFIR_MD
Interface Mode1 Register
Interface Mode4 Register
SBIST FIR_UDR
IFA B_O
TLE5012B E1000 (IIF)
1 1 0 1 1 0001 0 0 0 0
TLE5012B E3005 (HSM)
1 1 0 1 1 0100 0 0 1 0
TLE5012B E5000 (PWM)
1 0 0 0 0 0000 0 0 0 1
TLE5012B E5020 (PWM)
1 1 1 0 0 0000 1 1 0 1
TLE5012B E9000 (SPC)
1 0 1 0 0 0000 0 0 1 1
msb lsb msb lsb msb lsb
ms
IFAB_HYS
Temp. Coeff. Reg.
IFAB_RES IF_MD
Interface Mode3 Registe
A NG_DIR PREDICT SPIKEF SSC_OD
TLE5012B E1000 (IIF)
00010000000 0 0 0 1 0 0 0 0
TLE5012B E3005 (HSM)
00010000000 0 1 0 1 0 0 0 0
TLE5012B E5000 (PWM)
00010000000 0 0 0 0 1 0 1 0
TLE5012B E5020 (PWM)
00010000000 0 0 1 0 1 0 1 0
TLE5012B E9000 (SPC)
00010000000 0 0 0 0 1 0 1 0
msb lsb
msb
msb
lsb
Interface Mode2 Register
ANG_RANGE
UTOCA