TLE5012B
Interfaces
User’s Manual 63 Rev. 1.2, 2018-02
Table 5-13 Incremental Interface
Parameter Symbol Values Unit Note / Test Condition
Min. Typ. Max.
Incremental output frequency f
Inc
1.0 MHz Frequency of phase A and
phase B
1)
1) Not subject to production test - verified by design/characterization
Index pulse width t
0°
5 μs0°
1)