TLE5012B
Interfaces
User’s Manual 45 Rev. 1.2, 2018-02
Figure 5-10 Flow-Chart of Angle Calculation from the X-raw and Y-raw values
5.2.5.2 Angle Calculation with end-of-line calibration values
The TLE5012B already has pre-calibrated compensation parameters which can be used to calculate the angle
value (see Chapter 5.2.5.1). Own compensation parameters can also be calculated end-of-line if desired. In that
case check the Application Note TLE5009 Calibration.
Angle
Calculation
Non-Orthogonality
Correction
Amplitude
Normalization
Temperature-dependent
Offset Calculation
Offset
Compensation
readT_RAW
10bits
readT25O
7bits
T_RAW
10bits
T25O
7bits
439
readTCO_X_T
7bits
readTCO_Y_T
7bits
readX_OFFSET
12bits
Ox
12bits
+
x
readY_OFFSET
12bits
Oy
12bits
+
x
readSYNCH
12bits
x
Y1
16bits
readADC_X
16bits
readADC_Y
16bits
+
X1
16bits
+
Y2
16bits
X2
16bits
readORTHO
12bits
sin(ORTHO)
cos(ORTHO)
/
x
Y3
16bits
X3
16bits
readANG_BASE
12bits
α
atan(Y3/X3)
SYNCH
14bits
>>7
>>7
+2^14
>>14

Table of Contents