TLE5012B
Pre-Configured Derivates
User’s Manual 102 Rev. 1.2, 2018-02
7 Pre-Configured Derivates
Derivates of the TLE5012B are available with different pre-configured register settings for specific applications.
The default configuration of all derivates is described below (see Chapter 7.6 for the respective fuse configuration)
and can be changed at start-up via SSC interface.
7.1 IIF-type: E1000
The TLE5012B E1000 is preconfigured for Incremental Interface and fast angle update rate (42.7 μs). It is most
suitable for BLDC motor commutation.
Incremental Interface A/B mode.
12bit mode, one count per 0.088° angle step.
Absolute count enabled.
Autocalibration mode 1 enabled.
Prediction disabled.
Hysteresis set to 0.703°.
IFA/IFB/IFC pins set to push-pull output.
SSC interface’s DATA pin set to push-pull output.
IFA/IFB/IFC pins set to strong driver, DATA pin set to strong driver, fast edge.
Voltage spike filter on input pads disabled.
7.2 HSM-type: E3005
The TLE5012B E3005 is preconfigured for Hall-Switch-Mode and fast angle update rate (42.7 μs). It is most
suitable as a replacement for three Hall switches for BLDC motor commutation.
Number of pole pairs is set to 5.
Autocalibration mode 1 enabled.
Prediction enabled.
Hysteresis set to 0.703°.
IFA (HS1)/IFB (HS2)/IFC (HS3) pins set to push-pull output.
SSC interface’s DATA pin set to push-pull output.
IFA/IFB/IFC pins set to strong driver, DATA pin set to strong driver, fast edge.
Voltage spike filter on input pads disabled.
7.3 PWM-type: E5000
The TLE5012B E5000 is preconfigured for Pulse-Width-Modulation interface. It is most suitable for steering angle
and actuator position sensing.
PWM frequency is 244 Hz.
Filter update time is 85.4 μs.
Error indication enabled.
Autocalibration disabled
Prediction disabled
Hysteresis disabled.
IFA (PWM) pin set to push-pull output.
SSC interface’s DATA pin set to push-pull output.
IFA/IFB/IFC pins set to weak driver, DATA pin set to medium driver, fast edge.
Voltage spike filter on input pads enabled.