Action
Comments
Dispensing:
Single-byte response indicating that a dispense operation
is in progress. The four-byte value of the note or the
single byte channel number is reported, depending on the
reporting type set. This value will be 0 until the note has
passed out of the Note Float module and into a payable
position in the validator.
Dispensed:
Response that indicates when the payout has finished a
dispense operation; The four-byte value of the note or the
single byte channel number is reported, depending on the
reporting type set.
Jammed:
Five byte response that indicates that the payout is
jammed; this is reported until it is un-jammed or reset. It
will also become disabled. The value or channel number of
the note being dispensed is also reported.
Incomplete Payout:
This event is given when the payout starts up if a payout
or float operation was in progress when the power was
removed. The first four bytes after the event code are the
value that was dispensed; the next four are the value that
was originally requested.
Emptying:
This event is given while the payout is being emptied of
notes into the cashbox by the EMPTY command.
Empty:
This event is given at the end of the empty process.
Note Stored in
Payout:
This event is given when notes paid in to the payout
system are routed to the payout store. For compatibility
with the SMART Payout the value of the note is not
reported. However if the Note Float is enabled with the
option flag VALUE_ON_STORED set, then the value of the
note will be reported (see enable payout device
command).
Note Transferred to
Stacker:
This event is given when a note has successfully been
moved from the Note Float and stacked in the cash box.
During the process the Stacking event will be given.
Note Float Removed:
This event is reported when the Note Float module is
physically disconnected from the validator while the power
is on.
Note Float Attached:
This event is reported when the Note Float module is
physically attached to the validator while the power is on.
The validator and Note Float module will then reset.
Note In Bezel Hold:
This event is reported when the Dispensing note is held in
the bezel waiting for the user to remove it.