Commissioning and Trial Run
‑67‑
Param
eter
Code
Parameter
Name
Value Default Description
A6‑00 Minimum
input of AI
curve 4
‑10.00 V to A6‑02 0.00 V These parameters define AI curve 4. A6‑00 and A6‑02,
A6‑04 and A6‑06 are interlocked.
A6‑01 Percentage
corresponding
to minimum
input of AI
curve 4
‑100.0% to +100.0% 0.0%
A6‑02 Inflection
point 1 input
of AI curve 4
A6‑00 to A6‑04 3.00 V
A6‑03 Percentage
corresponding
to inflection
point 1 input
of AI curve 4
‑100.0% to +100.0% 30.0%
A6‑04 Inflection
point 2 input
of AI curve 4
A6‑02 to A6‑06 6.00 V
A6‑05 Percentage
corresponding
to inflection 2
input of AI
curve 4
‑100.0% to +100.0% 60.0%
A6‑06 Maximum
input of AI
curve 4
A6‑04 to 10.00 V 10.00 V
A6‑07 Percentage
corresponding
to maximum
input of AI
curve 4
‑100.0% to +100.0% 100.0%