2 Mechanical Installation                                                                                                                      
 
- 30 -
Power Rating Clearance Requirements (mm)
5.5–30 kW A ≥ 10
37–45 kW A ≥ 50
55–160 kW A ≥ 50
 
◆
For Structures T10 to T12, only one AC drive can be installed in a cabinet. 
If multiple AC drives need to be installed side by side, contact Inovance or 
the agent.
3)  Installing AC drives above one another
In scenarios where AC drives are installed above one another, an air guide plate must be 
installed to avoid overtemperature of the upper AC drive caused by heat generated by 
the lower AC drive.
"JSHVJEFQMBUF
"$ESJWF
"$ESJWF
Figure 2-6 Installing AC drives (structures T2 to T9) above one another
 
◆
Structures T10 to T12 cannot be installed above one another.