2 Mechanical Installation
- 36 -
NOTE
Reserve the installation clearances as speci󶍾ed in Figure 2-4 to ensure
su󶎀cient space for heat dissipation of the AC drive. Take the heat
dissipation of other equipment in the cabinet into consideration.
A tool such as a sleeve with an extension bar is required for operation on
the copper busbar terminals of main circuit power cables.
Make sure to align the casters to the guide rail and arrange two persons
for drive push-in and pull-out to ensure safety, as shown in Figure 2-18
and Figure 2-19.
See Figure 2-12 for cabinet layout before mounting the AC drive in a
cabinet. The dimensions of cabinet rack are 2200 x 800 x 600 (H200
cabinet ventilation top cover included, unit: mm). The H100 cabinet base
is required for installing the cabinet. A windscreen must be installed on
the cabinet top to avoid circulation of hot air inside the cabinet. Air inlets
must be provided at the lower part of the cabinet door.
For details about dimensions of the mounting bracket (delivered with the
product), see
"2.5.4 Dimensions of the Mounting Bracket"
. Besides, check
that the strength and sti󶍽ness of the guide rail meet requirements.
After the AC drive is pushed into the cabinet, remove the paperboard
from the air outlet of the AC drive to exhaust hot air, preventing the
overtemperature fault.
0VUQVUDPQQFSCVTCBS
$BCJOFUUPQBJS
PVUMFUDPWFS
$BCJOFU
$JSDVJUCSFBLFS
$POUBDUPS
"$JOQVUSFBDUPS
"JSJOMFUPGGSPOUEPPS
*OTVMBUJPOCBSSJFS
$BCJOFUJOQVU
UFSNJOBM
"$ESJWFHSPVOEJOHUFSNJOBMT
7FOUJMBUJPOBJS珞PX
$BCJOFUGSPOUEPPS
5SBOTGPSNFSGSPN
7UP7
) DBCJOFUCBTF
 NN
 NN
"$ESJWFL8
Figure 2-12 Recommended cabinet layout