36 i3/i4 Satellite Antenna System Install and User Manual
1) Parameter Setting method
SCAN OFFSET The actual angle between the marked point on
the sub-reflector and the datum.
TRACK SCALE – To control the tracking speed while antenna is tracking
the satellite. High Track Scale value resulting in high tracking speed.
DETECT LEVEL The basic single detection level.
TRACKING LEVEL – The basic signal tracking level
EL ADJUST – The mechanical tolerance compensation of elevation limit.
WRS LEVEL The basic WRS detection level.
POWER THRESHOLD – The value to identify Vertical/Horizontal or
RHCP/LHCP.
DISEQC LEVEL The value to identify 22KHz tone.
OFFSET RH-LH – The difference value between RHCP/LHCP and
SCAN OFFSET.
USE WRS To apply WRS while antenna is searching for satellite.
OFFSET DIFFERENCE To apply Offset Difference.