50
24-Port Gigabit Ethernet PoE+ Web-Managed Switch with
4 Gigabit Combo Base-T/SFP Ports
User Manual
ALARM GROUP
Item Description
Index Specify the alarm table index number.
Static table Specify the MIB variable that is monitored by the alarm entry.
Statistical group
index
This is the number of samples (“buckets”) to keep before they get overwritten.
Sampling time
interval
The number of seconds in each polling cycle.
Sample type This is the method of sampling the selected variable and calculating the value to be
compared against the thresholds.
Owner Optional eld that allows the network administrator to enter the name of the owner of
the Alarm RMON group.
The alarm
threshold limit
This is the rising threshold, a number at which the alarm is triggered. This value ranges
between 0 and 2147483647.
Events exceeding
threshold
The event number to trigger when the rising threshold exceeds its limit.
Alarm threshold
limit
This is the falling threshold, a number at which the alarm is reset. This value ranges
between 0 and 2147483647.
Events below
threshold limit
The event number to trigger when the falling threshold exceeds its limit.