Chapter 4 — Configuration Command Reference
SF51 Cordless Scanner User’s Guide 45
ISBT 128
Enables and configures decoding of ISBT Code 128 symbology.
ISBT Code 128 is the global bar code labeling standard for the
blood banking industry. It is used to support the worldwide
distribution, tracking, and handling of blood bags and blood
components.
GTIN Processing for EAN 128
With GTIN processing enabled, a GTIN compliant EAN 128
label will have the first two digits stripped and output 14 digits.
A GTIN (Global Trade Item Number) compliant EAN 128
label:
is 16 digits long.
has “01” as the first two digits of the label.
Configuration Modes and Utilities
Use Configuration Modes and Utilities to:
allow the SF51 to always accept configuration commands by
scanning bar codes or to timeout 1 minute after the last
configuration command is set by scanning a bar code.
get the product version, sub-system versions, and Bluetooth
address of your SF51.
page the SF51 from your host PC or turn off the SF51.
For more information and bar codes, see “Calling Product
Support” on page 28.
Consecutive Same Read Data Validation
To increase decode security, you can have the scanner scan a bar
code multiple times to ensure you have a valid read before
transmitting the data.
You can set Consecutive Same Read Data Validation from 0 to
10. The default value of 0 sets the scanner to automatically
adapt the consecutive same read based on the bar code quality
and the trust level of the bar code. For example, labels with a
check digit require less reads than labels without a check digit.

Table of Contents

Other manuals for Intermec SF51

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermec SF51 and is the answer not in the manual?

Intermec SF51 Specifications

Capacity and Output IconCapacity and Output
maximum output voltage4.1 V
mean output voltage3.7 V
capacity2400 mAh
Temperature and Humidity IconTemperature and Humidity
operating temperature range-20°C to 50°C
charging temperature range0°C to 35°C
storage temperature range-20°C to 60°C
recommended storage temperature21°C
humidity range0 to 95% non-condensing
Weight and Dimensions IconWeight and Dimensions
length73 mm
diameter19 mm
weight55 g