Product information
Health indicator lights
So-called health or status indicator lights are used to monitor the current values of the RollerDrive.
Health indicator lights are used to check the
Temperature
Power
Frequency of errors
Temperature
Green RollerDrive temperature OK.
Yellow The temperature of the RollerDrive has reached the warning limit.
Red The temperature of the RollerDrive has exceeded a critical value.
Power
Green The RollerDrive is working within the specied power limits.
Yellow The rated power of the RollerDrive has been exceeded.
Red The power of the RollerDrive is > 120% of the rated power.
Frequency of errors
The frequency of the following errors is monitored within a specied time frame:
Heavy running
Stall timing
Overvoltage
Undervoltage
Green Status of the RollerDrive OK.
Yellow The number of errors within the specied time frame has reached the warning limit.
Red The number of errors within the specied time frame has reached a critical limit.
The indicator lights are used purely for information purposes and do not result in the shutdown of the
RollerDrive.
The signals can be evaluated and processed via the connected control system.